Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Medicina (B Aires) ; 84(1): 148-152, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38271942

RESUMO

In patients with chronic obstructive pulmonary disease (COPD), single lung transplantation (SLT) is sometimes performed as an alternative to bilateral lung transplantation due to limited organ availability. However, the postoperative management of SLT presents challenges, including complications related to the distinct compliance of each lung. This case report presents the case of a 65-year-old male patient who underwent SLT and was in the weaning period from mechanical ventilation. High-flow oxygen therapy (HFOT) was administered, and the physiological effects were measured using electrical impedance tomography (EIT). The results demonstrated that the application of HFOT increased air trapping and overdistention in the native lung without benefiting the transplanted lung. HFOT through a tracheostomy tube or nasal cannula resulted in a more heterogeneous distribution of ventilation, with increased end expiratory lung impedance, prolonged expiratory time constants, and an increase in silent spaces. The drop in tidal impedance after applying HFOT did not indicate hypoventilation but rather overdistention and air trapping in the native lung, while the transplanted lung showed evidence of hypoventilation. These findings suggest that HFOT may not be beneficial for SLT patients and could potentially worsen outcomes. However, due to the limited scope of this case report, further prospective studies with larger patient cohorts are needed to confirm these results.


En pacientes con enfermedad pulmonar obstructiva crónica (EPOC), el trasplante pulmonar unilateral (SLT, por sus siglas en inglés) se realiza como alternativa a la disponibilidad limitada de donantes para el trasplante pulmonar bilateral. Sin embargo, el manejo postoperatorio del SLT presenta desafíos, incluyendo complicaciones relacionadas con la distinta complacencia de cada pulmón. Este reporte presenta el caso de un paciente varón de 65 años que fue sometido a un SLT y se encontraba en el proceso de destete de la ventilación mecánica. Se administró terapia de oxígeno de alto flujo (HFOT, por sus siglas en inglés) y se midieron los efectos fisiológicos utilizando la tomografía de impedancia eléctrica (EIT, por sus siglas en inglés). Los resultados demostraron que la aplicación de HFOT aumentó la retención de aire y la hiperinflación en el pulmón nativo sin beneficiar al pulmón trasplantado. Tanto la HFOT a través de un tubo de traqueostomía como a través de cánula nasal resultaron en una distribución más heterogénea de la ventilación, con un aumento en la impedancia pulmonar al final de la espiración, prolongación de las constantes de tiempo espiratorias y un aumento en los espacios silentes. La disminución de la impedancia tidal después de aplicar HFOT no indicó hipoventilación, sino más bien hiperinsuflación y retención de gas en el pulmón nativo, mientras que el pulmón trasplantado mostró evidencia de hipoventilación. Estos hallazgos sugieren que el HFOT puede no ser beneficioso para los pacientes con SLT y podría empeorar los resultados. Sin embargo, debido al alcance limitado de este informe de caso, se necesitan estudios prospectivos con cohortes de pacientes más amplias para confirmar estos resultados.


Assuntos
Hipoventilação , Transplante de Pulmão , Masculino , Humanos , Idoso , Impedância Elétrica , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Pulmão/diagnóstico por imagem , Oxigênio , Tomografia/métodos
2.
Rev. bras. ter. intensiva ; 31(4): 483-489, out.-dez. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1058049

RESUMO

RESUMEN Objetivo: Describir el comportamiento del componente resistivo ante el incremento de la presión positiva espiratoria final (PEEP) en pacientes con síndrome de distrés respiratorio agudo ventilados con una estrategia de ventilación protectora. Métodos: En modo controlada por volumen, a 6mL/Kg y flujo constante se realizaron oclusiones teleinspiratorias a PEEP 0, 5 10, 15 y 20cmH2O. Se obtuvieron valores de presión pico, inicial, plateau y se calculó resistencias máxima, mínima y diferencial. Las comparaciones se realizaron mediante test de ANOVA para muestras relacionadas con corrección post hoc de Bonferroni. Se consideró significativo una p < 0,05. Resultados: La resistencia máxima más elevada se observó en los niveles de PEEP más bajos. Los valores de PEEP 10 y 15cmH2O tuvieron diferencias significativas con PEEP 5 y 0cmH2O, mientras que PEEP 20cmH2O únicamente con PEEP 0cmH2O (p < 0,05). La resistencia mínima tuvo la misma conducta que la resistencia máxima. A partir de PEEP 10cmH2O todos tuvieron diferencias significativas con PEEP 0 y 5cmH2O (p < 0,05). La resistencia diferencial se expresó de manera opuesta a la resistencia máxima y mínima. El único nivel de PEEP que experimentó diferencias significativas con PEEP 0 y 5cmH2O fue PEEP 20cmH2O. También hubo diferencias entre PEEP 15 y PEEP 5cmH2O (p < 0,05). Conclusiones: Durante ventilación protectora en pacientes com síndrome de distrés respiratorio agudo, la resistencia máxima del sistema respiratorio tiene un comportamiento decreciente con la PEEP y refleja la respuesta que tiene la resistencia mínima. Mientras que la resistencia diferencial mantiene su conducta creciente con los valores de PEEP.


ABSTRACT Objective: To describe the behavior of inspiratory resistance components when positive end-expiratory pressure (PEEP) increases in patients with acute respiratory distress syndrome under a protective ventilation strategy. Methods: In volume-controlled mode, at 6mL/kg and constant flow, end-inspiratory occlusions were performed at 0, 5 10, 15 and 20cmH2O PEEP. Peak, initial and plateau pressure values were assessed, calculating the maximum, minimum and differential resistances. The results were compared by repeated measures analysis of variance (ANOVA) with post hoc Bonferroni correction, considering p < 0.05 significant. Results: The highest maximum resistance was observed at the lowest PEEP levels. The values for 10 and 15cmH2O PEEP significantly differed from those for 5 and 0cmH2O PEEP, whereas that for 20cmH2O PEEP only significantly differed from that for 0cmH2O PEEP (p < 0.05). The minimum resistance behaved similarly to the maximum resistance; the values for PEEP levels from 10cmH2O to 20cmH2O significantly differed from those for 0 and 5cmH2O PEEP (p < 0.05). Differential resistance showed the opposite variation to the maximum and minimum resistances. The only PEEP level that showed significant differences from 0 and 5cmH2O PEEP was 20cmH2O PEEP. Significant differences were also found between 15 and 5cmH2O PEEP (p < 0.05). Conclusions: During protective ventilation in patients with acute respiratory distress syndrome, the maximum resistance of the respiratory system decreases with PEEP, reflecting the minimum resistance response, whereas differential resistance increases with PEEP.


Assuntos
Humanos , Masculino , Feminino , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Mecânica Respiratória/fisiologia , Respiração com Pressão Positiva , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Volume de Ventilação Pulmonar , Estudos Transversais , Estudos Retrospectivos
3.
Rev Bras Ter Intensiva ; 31(4): 483-489, 2019.
Artigo em Espanhol, Inglês | MEDLINE | ID: mdl-31967222

RESUMO

OBJECTIVE: To describe the behavior of inspiratory resistance components when positive end-expiratory pressure (PEEP) increases in patients with acute respiratory distress syndrome under a protective ventilation strategy. METHODS: In volume-controlled mode, at 6mL/kg and constant flow, end-inspiratory occlusions were performed at 0, 5 10, 15 and 20cmH2O PEEP. Peak, initial and plateau pressure values were assessed, calculating the maximum, minimum and differential resistances. The results were compared by repeated measures analysis of variance (ANOVA) with post hoc Bonferroni correction, considering p < 0.05 significant. RESULTS: The highest maximum resistance was observed at the lowest PEEP levels. The values for 10 and 15cmH2O PEEP significantly differed from those for 5 and 0cmH2O PEEP, whereas that for 20cmH2O PEEP only significantly differed from that for 0cmH2O PEEP (p < 0.05). The minimum resistance behaved similarly to the maximum resistance; the values for PEEP levels from 10cmH2O to 20cmH2O significantly differed from those for 0 and 5cmH2O PEEP (p < 0.05). Differential resistance showed the opposite variation to the maximum and minimum resistances. The only PEEP level that showed significant differences from 0 and 5cmH2O PEEP was 20cmH2O PEEP. Significant differences were also found between 15 and 5cmH2O PEEP (p < 0.05). CONCLUSIONS: During protective ventilation in patients with acute respiratory distress syndrome, the maximum resistance of the respiratory system decreases with PEEP, reflecting the minimum resistance response, whereas differential resistance increases with PEEP.


OBJETIVO: Describir el comportamiento del componente resistivo ante el incremento de la presión positiva espiratoria final (PEEP) en pacientes con síndrome de distrés respiratorio agudo ventilados con una estrategia de ventilación protectora. MÉTODOS: En modo controlada por volumen, a 6mL/Kg y flujo constante se realizaron oclusiones teleinspiratorias a PEEP 0, 5 10, 15 y 20cmH2O. Se obtuvieron valores de presión pico, inicial, plateau y se calculó resistencias máxima, mínima y diferencial. Las comparaciones se realizaron mediante test de ANOVA para muestras relacionadas con corrección post hoc de Bonferroni. Se consideró significativo una p < 0,05. RESULTADOS: La resistencia máxima más elevada se observó en los niveles de PEEP más bajos. Los valores de PEEP 10 y 15cmH2O tuvieron diferencias significativas con PEEP 5 y 0cmH2O, mientras que PEEP 20cmH2O únicamente con PEEP 0cmH2O (p < 0,05). La resistencia mínima tuvo la misma conducta que la resistencia máxima. A partir de PEEP 10cmH2O todos tuvieron diferencias significativas con PEEP 0 y 5cmH2O (p < 0,05). La resistencia diferencial se expresó de manera opuesta a la resistencia máxima y mínima. El único nivel de PEEP que experimentó diferencias significativas con PEEP 0 y 5cmH2O fue PEEP 20cmH2O. También hubo diferencias entre PEEP 15 y PEEP 5cmH2O (p < 0,05). CONCLUSIONES: Durante ventilación protectora en pacientes com síndrome de distrés respiratorio agudo, la resistencia máxima del sistema respiratorio tiene un comportamiento decreciente con la PEEP y refleja la respuesta que tiene la resistencia mínima. Mientras que la resistencia diferencial mantiene su conducta creciente con los valores de PEEP.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório/terapia , Mecânica Respiratória/fisiologia , Estudos Transversais , Feminino , Humanos , Masculino , Respiração Artificial/métodos , Síndrome do Desconforto Respiratório/fisiopatologia , Estudos Retrospectivos , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...